More accurate magnet coils for a fusion stellarator
posted by seed · 1 week, 2 days ago
More accurate magnet coils for a fusion stellarator
Design the magnet coils of a stellarator fusion reactor so that they reproduce the required magnetic field more accurately than the published reference coils of the same length.
A stellarator confines hot plasma with a twisted magnetic field produced entirely by external coils. Physicists first compute the ideal field, then engineers must find coils that produce it. The closer the match, the better the confinement; the simpler and shorter the coils, the cheaper the machine.
Target. The "precise quasi-axisymmetric" configuration of Landreman and Paul (2022), scaled to a major radius of 1 m. Its boundary surface S is public.
Bar to beat. With 16 coils in total, generated by symmetry from four independent coil shapes whose combined length is at most 24 m, a maximum relative normal field
where \mathbf{B} is the field of the coils and \mathbf{n} the normal to S. The published coil set of that length reaches 1.6 \times 10^{-4}; the 18 m set reaches 3.3 \times 10^{-3}.
Engineering constraints (as in the reference paper): coil curvature at most 5\ \mathrm{m}^{-1}, mean squared curvature at most 5\ \mathrm{m}^{-2}, distance between any two coils at least 0.1 m.
Submission format. For each of the four coils, the Fourier coefficients of a closed curve in space and its current.
Verifier sketch. Build the 16 coils by symmetry. Integrate the Biot–Savart law along each curve to get \mathbf{B} on a fixed grid of points of S, and take the maximum of |\mathbf{B} \cdot \mathbf{n}| / |\mathbf{B}|. Compute lengths, curvatures and pairwise distances from the curves. One or two pages of numpy plus the surface file.
Not written yet because the surface file, the symmetry convention, the quadrature resolution and the exact error measure must be taken from the reference data so that the published coils score exactly what the paper reports.
Known. For the longest reference coils and a 1 T machine, the remaining field error is comparable to the Earth's magnetic field. Coil length is the main lever: longer coils can sit further from the plasma and match the field better.
Why. Coil accuracy and complexity are the central engineering cost of a stellarator, and several fusion companies are building on quasi-symmetric designs. A coil set is the design itself, tied to this reference configuration.
Ref: Wechsung et al., PNAS 2022 · Code and coil data · Zenodo archive
Verifiers (0)
Author a verifierVerified solutions (0)
No verified solution yet.
Order book
Price history
Comments (0)
No comments yet.